Thank you for choosing PurchasingEfficiency.com to source Part Number FCB-205-325 with an NSN 5945013913718. Purchasing Efficiency is a leading website for purchasing long lead-time, hard to find, and obsolete parts, as well as new and used parts.
Please complete the RFQ form for part number FCB-205-325 with 00213 and a dedicated product expert will be in touch with you within 15 minutes to discuss your quote for part number FCB-205-325, NSN 5945013913718, and manufactured by Struthersdunn Llc.
Part Number FCB-205-325 Specification |
||
---|---|---|
Part Number: FCB-205-325 | Manufacturer: Struthersdunn Llc | CAGE Code: 00213 |
NSN: 5945-01-391-3718 | Item Name: relay electromagnet | |
FSC: 5945 Relays and Solenoids | Alternate P/N : FCB205325 |
“*” Symbols for mandatory fields
We stock more than 25 million parts from 5,100+ recognized manufacturers. All orders are supplied through California, comprising of a comprehensive product inventory. For any additional queries, you can contact us 24/7 on our toll-free number: +1-714-705-4780 or e-mail us at sales@purchasingefficiency.com
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.078 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 0.640 INCHES MAXIMUM" |
ABTD | MOUNTING SLOT WIDTH | 0.133 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC AND VIBRATION PROOF" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS MINIMUM SINGLE WINDING AND 550.0 OHMS MAXIMUM SINGLE WINDING" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC MOTOR LOAD AND 2.0 AMPERES DC MOTOR LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC" |
FEAT | SPECIAL FEATURES | FAILURE RATE: 0.3 PERCENT PER 10,000 CYCLES" |
TEST | TEST DATA DOCUMENT | 07690-633108 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI" |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS" |
ABHP | OVERALL LENGTH | 1.078 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 0.410 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 0.640 INCHES MAXIMUM" |
ABTD | MOUNTING SLOT WIDTH | 0.133 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC AND VIBRATION PROOF" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS MINIMUM SINGLE WINDING AND 550.0 OHMS MAXIMUM SINGLE WINDING" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC MOTOR LOAD AND 2.0 AMPERES DC MOTOR LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC" |
FEAT | SPECIAL FEATURES | FAILURE RATE: 0.3 PERCENT PER 10,000 CYCLES" |
TEST | TEST DATA DOCUMENT | 07690-633108 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI" |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS" |
Warrantied inventory at competitive prices
Search the world's largest inventory of electronic components
All inventory ready to ship from our sellers
We sell only warrantied and traceable parts
Top NSN and Aviation Part Types |
---|
Siphon |
Main Rotor Damper Assy |
Multiload Module |
Flange |
Smoke Det |
Plate Assy |
Plug Tip |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’d Like to Stay Up to Date On the Newest Parts That We offer, Kindly Go Through Our Aircraft Parts Catalog.
Request for Quote